- Xylem Analytics Germany (WTW)
- Testo SE & CO KGaA
- A&D Instruments Limited
- ATAGO CO.,LTD
- Kern & Sohn GmbH
- Mettler-Toledo Online GmbH
- A. Krüss Optronic GmbH
- Sartorius Lab Instruments
- IKA-Werke GmbH & Co.KG
- Xylem Analytics Germany (SI)
- MOTIC Deutschland GmbH
- LLG Labware
- Ludwig Schneider GmbH & Co.KG
- Anton Paar Germany GmbH
- Tintometer GmbH
- Reagecon Diagnostics Ltd.
- Heathrow Scientific LLC
- ISOLAB Laborgeräte GmbH
- Xylem Analytics Germany (EBRO)
- TFA Dostmann GmbH & Co.KG
- Lamy Rheology SARL
- Amarell GmbH & Co KG
- Bel-Art Products
- Lenz-Laborglas GmbH & Co. KG
- Hirschmann Laborgeräte GmbH
- H. & K. Starke GmbH
- Ohaus GmbH
- Knick Elektronische
- Hanhart 1882 GmbH
- Thermax
- Macherey-Nagel GmbH & Co. KG
- Industrial Physics Inks
- BRAND GMBH + CO.KG
- Günther Ehle Glasinstrumenten-
- Kartell S.p.A.
- BOCHEM Instrumente GmbH
- Scherf Präzision Europa GmbH
- Laborbedarf
- DOSTMANN electronic GmbH
- Hahnemühle FineArt GmbH
- Pinselmanufaktur Aulitzky
- Thermo Elect.LED GmbH (Eutech)
- Wagner & Munz GmbH
- Werner Dorsch GmbH
- Glaswarenfabrik Karl Hecht
- Büchi Labortechnik GmbH
- Köttermann GmbH
- IDCP B.V.
- Windaus-Labortechnik
- EUROTIME Uhrenvert. GmbH
- Cytiva Europe GmbH
- Mettler-Toledo GmbH (Prozesst)
- Cole-Parmer Ltd. (Stuart)
- Cole-Parmer Ltd. (Electro)
- Hamilton Bonaduz AG
- DWK Life Sciences GmbH (Kimble)
- Deutsche METROHM GmbH & Co.KG
- Cole-Parmer Ltd. (Jenway)
- GECO Gering
- Thermo Elect.LED GmbH (Orion)
- Mettler-Toledo GmbH (Waagen)
- HACH LANGE GmbH
- J.Engelsmann AG
- Thermo Electron GmbH (Haake)
- Bohlender GmbH
- Merck KGaA
- Fritz Arndt Frikmar KG
- Korsing Arbeitsschutz - MEWA
- Transport Control
- Cartamundi Deutschland GmbH
- 3M Deutschland GmbH
- Laborgeräte Süd GmbH & Co.KG
- VITLAB GmbH
- Altmann Analytik GmbH & Co.KG
- Paul Marienfeld GmbH & Co. KG
- Carl Friedrich Usbeck KG
- Hamilton Central Europe SRL
- The Tintometer Limited
- Water-i.d. GmbH
- DWK Life Sciences GmbH (Duran)
- Schorpp Gerätetechnik
- Endress+Hauser Conducta
Accessories
Analytical balances
Moisture balances
Other balances
Pocket balances
Precision balances
Weights
Analytical balances
Moisture balances
Other balances
Pocket balances
Precision balances
Weights
Buffer solutions
Electrode accessories
Ion selective Electrodes
Paper, chopstick
pH-Electrodes
Portable devices
Redox-Electrodes
Table devices
Electrode accessories
Ion selective Electrodes
Paper, chopstick
pH-Electrodes
Portable devices
Redox-Electrodes
Table devices
Overalls, coats, jackets, trousers
Overshoes, overboots, socks
Surgical masks, beard covers, hoods, sleeves
Overshoes, overboots, socks
Surgical masks, beard covers, hoods, sleeves
Chairs and stools
Gowing benches
Mats and floor coverings
Tables, shelves, trolleys, dispensers
Wardrobes
Gowing benches
Mats and floor coverings
Tables, shelves, trolleys, dispensers
Wardrobes
Components for Extraction
Components for reaction and distillation
Distillation-Accessories
Dropping Funnels
Flasks with NS joint neck
Flat ground flange reaction vessels
Gas wash bottles
Ground joints, attachable
KPG stirrer and bearings
Laboratory reactors
NS joints accessories
Reflux condenser
Standard ground stoppers
Stopcocks and Valves
Tubing adapters
Components for reaction and distillation
Distillation-Accessories
Dropping Funnels
Flasks with NS joint neck
Flat ground flange reaction vessels
Gas wash bottles
Ground joints, attachable
KPG stirrer and bearings
Laboratory reactors
NS joints accessories
Reflux condenser
Standard ground stoppers
Stopcocks and Valves
Tubing adapters
Biobanking
Cryogenic accessories
Cryogenic boxes
Cryogenic racks
Cryogenic storage tanks
Cryogenic tubes
Dewar flasks
Ice machines
Liquid nitrogen-Accessories
Low and Ultra low temperature freezers
Refrigerators and Freezers
Refrigerators and Freezers ex protected
Transport boxes
Cryogenic accessories
Cryogenic boxes
Cryogenic racks
Cryogenic storage tanks
Cryogenic tubes
Dewar flasks
Ice machines
Liquid nitrogen-Accessories
Low and Ultra low temperature freezers
Refrigerators and Freezers
Refrigerators and Freezers ex protected
Transport boxes
Concentration
DNA and RNA isolation
DNA-Electrophoresis
Electroporation
Gel-Documentation
PCR
PCR cabinets
Thermocyclers
DNA and RNA isolation
DNA-Electrophoresis
Electroporation
Gel-Documentation
PCR
PCR cabinets
Thermocyclers
Accessories and reagents
Dissecting sets
Embedding cassettes
Microtoms
Scalpels
Tissue floating baths
Dissecting sets
Embedding cassettes
Microtoms
Scalpels
Tissue floating baths
Cold light sources
Counting chambers
Digital microscopes and cameras
Light microscopes
Microscopy accessories
Slide covers
Slide storage
Slides
Staining racks
Stereomicroscopes
Counting chambers
Digital microscopes and cameras
Light microscopes
Microscopy accessories
Slide covers
Slide storage
Slides
Staining racks
Stereomicroscopes
Precision handheld instruments P700 series | Type: P705, Description: 2 channel, Pt100
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P705, Description: 2 channel, Pt100
€305,00
Precision handheld instruments P700 series | Type: P710, Description: 1 channel thermocouples Type K, J, L, N, T
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P710, Description: 1 channel thermocouples Type K, J, L, N, T
€205,00
Precision handheld instruments P700 series | Type: P715, Description: 2 channell thermocouples Type K, J, L, N, T
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P715, Description: 2 channell thermocouples Type K, J, L, N, T
€255,00
Precision handheld instruments P700 series | Type: P750, Description: 1 channel, Pt100, moisture, dew piont, flow
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P750, Description: 1 channel, Pt100, moisture, dew piont, flow
€480,00
Precision handheld instruments P700 series | Type: P755, Description: 2 channel, Pt100, moisture, dew point, flow
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P755, Description: 2 channel, Pt100, moisture, dew point, flow
€540,00
Precision handheld instruments P700 series | Type: P755-Log, Description: 2 channel, Pt100, moisture, dew point, flow, with datalogger for 6000 values
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P755-Log, Description: 2 channel, Pt100, moisture, dew point, flow, with datalogger for 6000 values
€630,00
Precision handheld instruments P700 series | Type: P770, Description: 2 channel, Pt100, moisture, dew point, flow
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P770, Description: 2 channel, Pt100, moisture, dew point, flow
€360,00
Precision handheld instruments P700 series | Type: P770-Log, Description: 2 channel, Pt100, moisture, dew point, flow, with datalogger for 6000 values
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P770-Log, Description: 2 channel, Pt100, moisture, dew point, flow, with datalogger for 6000 values
€480,00
Precision handheld instruments P700 series | Type: P795, Description: 2-channel, Pt100 for inspection equipment monitoring
Brand: DOSTMANN electronic GmbHAvailable in 11 variantsFor temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.Precision handheld instruments P700 series | Type: P795, Description: 2-channel, Pt100 for inspection equipment monitoring
€890,00
Pt100-Precision thermometer V215/V315 | Type: V215, Temperature: -50 ... 250 °C
Brand: DOSTMANN electronic GmbHAvailable in 2 variantsHighly accurate handheld measuring device for temperature measurement in liquids, air, and semi-solid (plastic or organic) materials.Resistance sensor Pt100 acc. to EN 60751MAX-MIN-AVG function°C/°F switchable0.5 second measuring intervalTemperature accuracy ±0.5 °C at -20 to 180 °CDisplay resolution selectable (0.01 or 0.1 °C/°F)Auto-OFF function after 10 minutesWith calibration certificate at 0/75/150 °CScope of supply: Pt100-Precision thermometer, 2 x AA batteries, bag, calibration certificate, operation manualPt100-Precision thermometer V215/V315 | Type: V215, Temperature: -50 ... 250 °C
€285,00
Pt100-Precision thermometer V215/V315 | Type: V315, Temperature: -50 ... 250 °C
Brand: DOSTMANN electronic GmbHAvailable in 2 variantsHighly accurate handheld measuring device for temperature measurement in liquids, air, and semi-solid (plastic or organic) materials.Resistance sensor Pt100 acc. to EN 60751MAX-MIN-AVG function°C/°F switchable0.5 second measuring intervalTemperature accuracy ±0.5 °C at -20 to 180 °CDisplay resolution selectable (0.01 or 0.1 °C/°F)Auto-OFF function after 10 minutesWith calibration certificate at 0/75/150 °CScope of supply: Pt100-Precision thermometer, 2 x AA batteries, bag, calibration certificate, operation manualPt100-Precision thermometer V215/V315 | Type: V315, Temperature: -50 ... 250 °C
€290,00
20%
Radio controlled wall clock | Type: Radio controlled wall clock, Measuring capacity hr: min: sec: 23:59:59, Acoustic alarm: No
Brand: DOSTMANN electronic GmbHHighest precision radio-controlled clockAnalogue display with second handDigital display of dateLarge dialIdeal for home, office, waiting room, lobby or entrance hall and as a giftØ 300mmBattery included 1,5 V AARadio controlled wall clock | Type: Radio controlled wall clock, Measuring capacity hr: min: sec: 23:59:59, Acoustic alarm: No
€31,92
Copyright © 2026 - Achrom nv - BE 0445.025.508 | General terms | Cookiebeleid | Privacybeleid | Handcrafted by CrayonCru®