Capacity µl
Depth mm
Description
Height mm
Length mm
Type
Width mm
Counting chamber according to Improved Neubauer (Petroff) | Description: without clamps, dark line, Depth mm: 0.02
Counting chamber according to Improved Neubauer (Petroff) | Description: without clamps, dark line, Depth mm: 0.02
Brand: Paul Marienfeld GmbH & Co. KGAvailable in 2 variantsCounting chamber with special depths (Petroff), Tolerance ±1 µm. For analysis of cell suspensions.With double rulingIn compliance with DIN ISO 12 847With 2 haemacytometer cover glasses 20 x 26 x 0.4 mmCounting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.Individually packed
€137,00
Counting chamber according to Improved Neubauer | Description: without clamps, bright line, Depth mm: 0.1
Counting chamber according to Improved Neubauer | Description: without clamps, bright line, Depth mm: 0.1
Brand: Paul Marienfeld GmbH & Co. KGAvailable in 4 variantsFor analysis of cell suspensions.With double rulingIn compliance with DIN ISO 12 847Tolerance of depth of chamber max. 2 %Counting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.With 2 haemacytometer cover glasses 20 x 26 x 0.4 mm
€68,35
Counting chamber according to Neubauer | Description: without clamps, dark line, Depth mm: 0.1
Counting chamber according to Neubauer | Description: without clamps, dark line, Depth mm: 0.1
Brand: Paul Marienfeld GmbH & Co. KGFor analysis of cell suspensions.With double rulingIn compliance with DIN ISO 12 847Tolerance of depth of chamber max. 2 %Counting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.With 2 haemacytometer cover glasses 20 x 26 x 0.4 mmIndividually packed
€33,80
Counting chamber according to Thoma | Description: Thoma, without clamps, dark line, Depth mm: 0.1
Counting chamber according to Thoma | Description: Thoma, without clamps, dark line, Depth mm: 0.1
Brand: Paul Marienfeld GmbH & Co. KGAvailable in 4 variantsFor analysis of cell suspensions.With double rulingIn compliance with DIN ISO 12 847Tolerance of depth of chamber max. 2 %Counting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.With 2 haemacytometer cover glasses 20 x 26 x 0.4 mmIndividually packed
€33,80
Counting Chamber, Bürker | Description: Without snap-on clips
Counting Chamber, Bürker | Description: Without snap-on clips
Brand: BRAND GMBH + CO.KGAvailable in 2 variantsBLAUBRAND®. Double ruling. With or without snap-on clips. Cell depth 0.1mm. The ruling shows 9 large squares of 1 mm2 each. These are used for counting leucocytes. Each large square is subdivided by double lines (0.05 mm apart) into 16 group squares with 0.2 mm sides. The group squares correspond in size to the Neubauer counting chamber, but have no further subdivisions. They are used for counting thrombocytes and erythrocytes. The double lines form mini squares with an area of 0.0025 mm2.
€57,80
Counting Chamber, Bürker-Türk | Description: Without snap-on clips
Counting Chamber, Bürker-Türk | Description: Without snap-on clips
Brand: BRAND GMBH + CO.KGAvailable in 2 variantsBLAUBRAND®. Double ruling. With or without snap-on clips. Cell depth 0.1mm. Combination of the Bürker and Thoma systems. The chamber depth is 0.1 mm. The ruling shows 9 large squares of 1 mm2 each. The large squares are subdivided into 16 group squares with 0.2 mm sides. In the central large square, each group square is subdivided into 16 mini squares with 0.05 mm sides (= 0.0025 mm2). For research and development only.
€57,80
Counting chamber, Fuchs-Rosenthal | Description: double ruling, without clamp
Counting chamber, Fuchs-Rosenthal | Description: double ruling, without clamp
Brand: Glaswarenfabrik Karl HechtAvailable in 2 variantsWith double ruling. Without snap-on clips. Calibratable.Cell depth 0.2mm. Grid has 16 x large 1 mm² squares. Each square is divided into 16 smaller squares each with a side length of 0.25mm and an area of 0.0625mm². These counting chambers are commonly used to count cells in cerebrospinal fluid.
€33,95
Counting Chamber, Fuchs-Rosenthal | Description: With snap-on clips
Counting Chamber, Fuchs-Rosenthal | Description: With snap-on clips
Brand: BRAND GMBH + CO.KGAvailable in 2 variantsBLAUBRAND®. Double ruling. With or without snap-on clips. Cell depth 0.2 mm. The ruling differs from the customary systems for blood cell counts by its large area of 16 mm2. The ruling shows 16 large squares of 1 mm2. Each large square is subdivided into 16 mini squares with 0.25 mm sides and an area of 0.0625 mm2. This chamber is frequently used for counting cells in the cerebrospinal fluid. For research and development only.
€81,70
Counting chamber, Improved Neubauer | Description: without clamp
Counting chamber, Improved Neubauer | Description: without clamp
Brand: BRAND GMBH + CO.KGAvailable in 2 variantsWith double ruling. Calibratable. Cell depth 0.1 mm. Same ruling as Improved Neubauer, but the large square in the centre is divided into 16 squares each with a side length of 0.25 mm. Unlike the more modern Improved Neubauer counting chambers, the counting area of each group square is limited by the outermost of the triple border lines.
€57,80
Counting chamber, Improved Neubauer | Description: without clamp, hell-linig
Counting chamber, Improved Neubauer | Description: without clamp, hell-linig
Brand: Glaswarenfabrik Karl HechtAvailable in 2 variantsWith double ruling. Calibratable. Cell depth 0.1 mm. Same ruling as Improved Neubauer, but the large square in the centre is divided into 16 squares each with a side length of 0.25 mm. Unlike the more modern Improved Neubauer counting chambers, the counting area of each group square is limited by the outermost of the triple border lines.
€70,15
Counting chamber, Improved Neubauer | Description: Without snap-on clips
Counting chamber, Improved Neubauer | Description: Without snap-on clips
Brand: Glaswarenfabrik Karl HechtBright line. With double ruling. Calibratable. Same counting grid as the Improved Neubauer cell, but with rhodium coated chamber base. Rulings are engraved into the Rhodium layer and appear bright under normal microscope settings. By altering the contrast it is possible to reverse the image under the microscope to make the rulings appear brighter or darker as required.
€71,25
Counting chamber, Improved Neubauer | Type: With snap-on clips
Counting chamber, Improved Neubauer | Type: With snap-on clips
Brand: BRAND GMBH + CO.KGAvailable in 2 variantsWith double ruling. Calibratable.Cell depth 0.1mm. Counting grid with 9 large squares each 1 mm². The 4 large squares in the corners for counting leucocytes are each subdivided into 16 squares with a side length of 0.25mm. The large square in the middle is subdivided into 25 squares each with a side length of 0.2mm. Each of these is further subdivided into 16 smaller squares each with a side length of 0.05 mm and an area of 0.0025mm². The 5 group squares marked with an 'E' are used to count thrombocytes and erythrocytes. All group squares have triple boundary lines on each side.
€81,70

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.