Please wait

Your message is being sent

An error occurred

Capillary columns GC BP1 | Int. diam. mm: 0.25, Length m: 60, Film thickness µm: 0.25
Capillary columns GC BP1 | Int. diam. mm: 0.25, Length m: 60, Film thickness µm: 0.25
Brand: Trajan Scientific Europe LtdAvailable in 42 variants100% Dimethyl Polysiloxane. General purpose GC column for all routine analyses such as hydrocarbons, aromatics, pesticides, phenol, herbicides and amines. Suitable replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.Low bleedNon-polar
€1.037,80
Capillary columns GC BP10 | Int. diam. mm: 0.32, Length m: 25, Film thickness µm: 0.5
Capillary columns GC BP10 | Int. diam. mm: 0.32, Length m: 25, Film thickness µm: 0.5
Brand: Trajan Scientific Europe LtdAvailable in 7 variants14 % Cyanopropylphenyl Polysiloxane. For analysis of organochlorine pesticides. Suitable replacement for: DB-1701, Rtx-1701, SPB-7, HP-1701, CP-Sil 19CB, 007-1701, PE-1701, SP-1701.Low bleedHighly inertAble to be solvent rinsed
€691,60
Capillary columns GC BP20 | Int. diam. mm: 0.32, Length m: 25, Film thickness µm: 0.50
Capillary columns GC BP20 | Int. diam. mm: 0.32, Length m: 25, Film thickness µm: 0.50
Brand: Trajan Scientific Europe LtdAvailable in 27 variantsPolyethylene Glycol phase. GC column for analyses such as alcohol, free acids, fatty acid methyl esters, aromatics, solvents and essential oils. Suitable replacement for: Carbowax 20M, CP-Wax 52 CB, DB-WAX, Elite-WAX, HP-20M, HP-INNOWax RH-WAX, Rtx-Wax, Stabilwax, SUPELCOWAX 10, TG-WaxMS, VF-WAXms, ZB-WAX.Industry standard wax columnPolar phase
€773,60
Capillary columns GC BP21 | Int. diam. mm: 0.32, Length m: 50, Film thickness µm: 0.5
Capillary columns GC BP21 | Int. diam. mm: 0.32, Length m: 50, Film thickness µm: 0.5
Brand: Trajan Scientific Europe LtdAvailable in 11 variantsNitroterephtalic acid modified PEG. For low molecular weight acids, alcohols, aldehydes, acrylates and ketones. Suitable replacement for: DB-FFAP, HP-FFAP, Stabilwax-DA, CPWax-58CB.Polar phaseAble to be solvent rinsed (water or methanol are not recommended for rinsing)
€1.375,90
Capillary columns GC BP5 | Int. diam. mm: 0.25, Length m: 30, Film thickness µm: 0.25
Capillary columns GC BP5 | Int. diam. mm: 0.25, Length m: 30, Film thickness µm: 0.25
Brand: Trajan Scientific Europe LtdAvailable in 17 variants5% Phenyl / 95% Dimethyl Polysiloxane. Low bleed. General purpose GC column for all routine analyses such as aromatics, pesticides, herbicides, hydrocarbons. Suitable replacement for: DB-5, Rtx-5, HP-5, Ultra-2, PTE-5, SPB-5, MDN-5, CP-Sil 8CB, VB-5, ZB-5, VF-5ms.
€648,50
Capillary columns GC BP5MS | Int. diam. mm: 0.18, Length m: 20, Film thickness µm: 0.18
Capillary columns GC BP5MS | Int. diam. mm: 0.18, Length m: 20, Film thickness µm: 0.18
Brand: Trajan Scientific Europe LtdAvailable in 5 variants5% Phenyl Polysilphenylene-siloxane. For 5% GC-MS analysis and general purpose MS analysis. Suitable replacement for: DB-5ms, ZB-5ms, Rxi-5Sil MS, VF-5ms, CP-Sil 8 CB.
€656,30
Capillary columns GC BPX-BIOD6584 | Int. diam. mm: 0.32, Length m: 10, Film thickness µm: 0.1
Capillary columns GC BPX-BIOD6584 | Int. diam. mm: 0.32, Length m: 10, Film thickness µm: 0.1
Brand: Trajan Scientific Europe LtdAvailable in 2 variantsOptimised for specified ASTM D6584 biodiesel methods.
€490,00
Capillary columns GC BPX-Dioxin | Int. diam. mm: 0.25, Length m: 60, Film thickness µm: 0.25
Capillary columns GC BPX-Dioxin | Int. diam. mm: 0.25, Length m: 60, Film thickness µm: 0.25
Brand: Trajan Scientific Europe LtdFor Dioxins and related compounds (POPs, PCBs, PCDFs, PCDDs).Very low bleedNon-polarExtremely inertIdeal for GC-MS
€1.324,50
Capillary columns GC BPX35 | Int. diam. mm: 0.1, Length m: 10, Film thickness µm: 0.1
Capillary columns GC BPX35 | Int. diam. mm: 0.1, Length m: 10, Film thickness µm: 0.1
Brand: Trajan Scientific Europe LtdAvailable in 7 variants35 % Phenyl Polysilphenylene-siloxane. Suitable Replacement for: DB-35, DB-35ms, Rtx-35, HP-35, HP-35MS, SPB-35, MDN-35.Very low bleedInertMid polarity columnEquivalent to USP phase G42High temperatureAble to be solvent rinsed
€423,40
Capillary columns GC BPX5 | Int. diam. mm: 0.25, Length m: 60, Film thickness µm: 1.00
Capillary columns GC BPX5 | Int. diam. mm: 0.25, Length m: 60, Film thickness µm: 1.00
Brand: Trajan Scientific Europe LtdAvailable in 37 variants5% Phenyl Polysilphenylene-siloxane. General purpose GC column for routine gas chromatographic analysis. Suitable replacement for: DB-5, DB-5ms, DB-5.625, XTI-5, Rtx-5ms, Ultra-2, HP-5, HP-5MS, HP5-TA, SPB-5, MDN-5S, CP-Sil8CB, Rxt-Sil 5MS, AT-5ms, VB-5, ZB-5, VF-5ms.Very low bleedNon-polarExtremely inert
€1.374,40
Capillary columns GC BPX608 | Int. diam. mm: 0.32, Length m: 25, Film thickness µm: 0.4
Capillary columns GC BPX608 | Int. diam. mm: 0.32, Length m: 25, Film thickness µm: 0.4
Brand: Trajan Scientific Europe Ltd35% Phenyl Polysilphenylene-siloxane. For environmental analyses, EPA 608, pesticides and herbicides. Suitable replacement for: DB-608, Rtx-35, SPB-608, HP-35, ZB-35.
€864,00
Capillary columns GC BPX70 | Int. diam. mm: 0.25, Length m: 30, Film thickness µm: 0.25
Capillary columns GC BPX70 | Int. diam. mm: 0.25, Length m: 30, Film thickness µm: 0.25
Brand: Trajan Scientific Europe LtdAvailable in 13 variants70% Cyanopropyl Polysilphenylene-siloxane. Able to be solvent rinsed. Industry standard column for fatty acid methyl esters, carbonhydrates, pharmaceuticals, GC/MS applications. Suitable alternative to: DB-23, Rtx-2330, SP-2330, CP-Sil 88, SP2380, HP-23.
€746,20

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.