Please wait

Your message is being sent

An error occurred

Exhaust air system for MCS-models
Exhaust air system for MCS-models
€690,02
Handle for autoclave type KL-12-2
Handle for autoclave type KL-12-2
€11,25
Heating Element for MCS-203, 204 and VA-MSC
Heating Element for MCS-203, 204 and VA-MSC
€187,08
Laboratory autoclave LaM-4-20-ECZ-J 20 ltr. up to 4 bar, with heating, white enamelled
Laboratory autoclave LaM-4-20-ECZ-J 20 ltr. up to 4 bar, with heating, white enamelled
€3.864,97
Laboratory autoclave LaM-4-20-MCS-J 20 ltr., up to 4 bar, 142°C, autom. temperature, white enamelled
Laboratory autoclave LaM-4-20-MCS-J 20 ltr., up to 4 bar, 142°C, autom. temperature, white enamelled
€4.819,21
Laboratory autoclave LaS-4-20 20 ltr. up to 4 bar, without heating, black silitated
Laboratory autoclave LaS-4-20 20 ltr. up to 4 bar, without heating, black silitated
€2.421,61
Laboratory autoclaves with heating | Type: La-MCS-203, Pressure bar: 3, Temperature °C: 143
Laboratory autoclaves with heating | Type: La-MCS-203, Pressure bar: 3, Temperature °C: 143
Brand: Maschinenbau Wolf GmbHAvailable in 5 variantsFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€5.940,48
Laboratory autoclaves with heating | Type: La-MCS-204, Pressure bar: 4, Temperature °C: 151
Laboratory autoclaves with heating | Type: La-MCS-204, Pressure bar: 4, Temperature °C: 151
Brand: Maschinenbau Wolf GmbHAvailable in 5 variantsFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€6.044,20
Laboratory autoclaves with heating | Type: La-VA-MCS, Pressure bar: 4, Temperature °C: 151
Laboratory autoclaves with heating | Type: La-VA-MCS, Pressure bar: 4, Temperature °C: 151
Brand: Maschinenbau Wolf GmbHAvailable in 5 variantsFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€6.846,68
Laboratory autoclaves with heating | Type: LaM-3-20-ECZ-J*, Pressure bar: 3, Temperature °C: 143
Laboratory autoclaves with heating | Type: LaM-3-20-ECZ-J*, Pressure bar: 3, Temperature °C: 143
Brand: Maschinenbau Wolf GmbHAvailable in 5 variantsFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€3.697,93
Laboratory autoclaves with heating | Type: LaM-3-20-MCS-J, Pressure bar: 3, Temperature °C: 143
Laboratory autoclaves with heating | Type: LaM-3-20-MCS-J, Pressure bar: 3, Temperature °C: 143
Brand: Maschinenbau Wolf GmbHAvailable in 5 variantsFor pressurised steam sterilisation. Temperature control is monitored via a built-in PT 100 sensor. With 1 min. to 100 hours timer.An accessory media probe (Cat. No. 9.842 070), also Pt 100, can be connected. If the "media probe" button is switched on, the autoclave cools down to 60°C after sterilisation and maintains this temperature until the unit is switched off. Culture media can therefore be processed more easily.Chamber and lid made of stainless steel.La-VA-MCS.Fully automatic, 4 bar. With solenoid valve for automatically venting and pulsing steam when sterilising liquids. Safety catch is only temperature dependent when used with accessory media probe.
€4.664,17
Level insert type T 2, 2-parts 23 x 12 cm
Level insert type T 2, 2-parts 23 x 12 cm
€107,50

Our website uses cookies.
Both we and our third-party partners use cookies. Some are strictly necessary for the site to function, but there are also optional cookies.

Necessary and functional cookies are always on. If you click "accept all cookies", you also accept the optional cookies. You can choose which cookies you want to enable via "set preferences".

Our website uses cookies.
What are cookies? What cookies do we use and why? Read more in our cookie policy

Necessary cookies

Cookies that are indispensable for your visit to the Website and the correct use thereof

Functional cookies

Cookies that make it easier and more pleasant for you to visit the Website, for example by personalising your browsing experience.

Performance cookies

Cookies that collect information about your use of the Website in order to improve the content of the Website and adapt it to the wishes of the User.

Third-party cookies

Cookies placed by third parties who offer their own services via the Website, such as social media, advertisements or video services.